The thesis describes the second phase of development of the Autonomous Crack Comparometer (ACC) system to incorporate measurements of ground motions and add several changes in the autonomous operation. In order to obtain the ground motion and air blast data, four additional transducers have been added. There are now a...
This thesis consists of the data and analysis of structural responses for two different studies: the Office of Surface Mining (OSM) study of the velocity response of “atypical” residential structures and the Autonomous Crack Monitoring (ACM) study. The main basis of this thesis was to do additional analysis on a...
This appendix synthesizes micrometer changes in crack width in response to both long term (environmental) and transient (blast vibration) of four of the structures in the main body. The appendix begins with a description of the genesis of the study and instruments employed. Response of the distressed wood-framed structure in...
Autonomous Crack Measurement (ACM) facilitates simultaneous measurement of crack response to environmental changes and vibrations produced by various construction activities. Dual-purpose crack displacement sensors measure crack response, while the vibration environment is defined by standard seismological transducers and the weather environment is defined as changes in temperature and humidity. This...
All structures have cosmetic cracks, which have no influence on structural integrity and usually remain unremarked until the structure’s occupants sense ground vibrations. Such vibrations are often associated with engineering activity, but are rarely responsible for cracks. However, this is difficult to prove without scientific basis. Automated Crack Monitoring (ACM)...
Cosmetic cracks are very common in structures, and most of the time they remain unnoticed and do not decrease the structural integrity. Although these cracks are unremarkable and barely noticeable, occupants become concerned about these cracks when construction occurs nearby. In order to investigate the true nature of these cracks,...
Crack and structural response to construction trench blasting was measured in a woodframe house with a stucco exterior. Blasts at distances between 232 m to 368 m produced peak particle velocities (PPV) and air blast over pressures (AB) of 9 mm/sec and 0.02 kPa (123 dB), respectively. Structural response velocities...
A unique judicial opportunity allowed measurement of the response of three cracks in residential structure to blasting for underground aggregate mining. Instrumented cracks were located in the interior basement CMU mortar and upstairs dry wall as well as exterior brick work. The dynamic environment was unusual. Even though the blasting...
Micro-meter dynamic crack responses in a two story structure to rock blasting- and wind gust- excitation are compared to those induced by long term climatological effects. These measurements substantiate the conservancy of the 12.5 mm/s (0.5 in./s) blasting vibration control to protect residential structures against cracking. The test structure was...
This paper describes the technology and methods deployed in the continuous autonomous remote monitoring of cracks in interior and exterior walls of a residence near a limestone quarry. The object is to quantitatively compare crack response to blast-induced ground motion to that induced by diurnal temperature changes, weather fronts, and...